Back To Top
Rosemount 3417 4+4 Dual-Configuration Gas Ultrasonic Flow Meter
Compteur de gaz à ultrasons double configuration Daniel 3417
Achieve the ultimate in fiscal measurement verification and validation with the fully-redundant Rosemount 3417 4+4 Ultrasonic Flow Meter that delivers the power of two field-proven Rosemount four-path, British Gas-design ultrasonic meters (certified to OIML R137 1&:2 Accuracy Class 0.
5) in a single body. This advanced meter generates two independent measurements on one meter run for superior measurement accuracy, reliability and uptime. Innovative MeterLink™ Software provides immediate access to a wealth of predictive diagnostics generated by the meter's ultra-fast 3410 Series Electronics for real-time detection of flow disturbances to reduce measurement uncertainty and simplify maintenance.

Daniel 2-in-1 Gas Ultrasonic Flow Meter Series Demo

Play Video

New Daniel Dual Configuration Gas Ultrasonic Meter 3410s series : Committed to improving natural gas measurement

Play Video

Daniel T-200 Transducer

Play Video
Rosemount 3417 4+4 Dual-Configuration Gas Ultrasonic Flow Meter

Specs

Line Sizes
DN200 to DN1050 (8-in to 42-in) with British Gas (BG) orientation
Fluid Type
Gas
Accuracy
±0.1% of reading relative over entire flow calibration range
Repeatability
±0.05% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s)
Velocity
Rated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 ft/s (38 m/s) on some sizes
Operating Temperature Range
  • T-21 Transducers: -20°C to +100°C (-4°F to +212°F)
  • T-22 Transducers: -50°C to +100°C (-58°F to +212°F)
  • T-200 Transducers (up to 42" line size): –50°C to 125°C (–58°F to +257°F)
Operating Pressure Range
  • T-21/T-22 Transducers: 689 to 27,579 kPag (100 to 4,000 psig)
  • T-21/T-22 Transducers: 345 kPag (50 psig) minimum operating pressure available with reduced Qmax
  • T-22 Transducers: 0 to 689 kPag (0 to 100 psig) isolated transducer mou
  • T-200 Transducers (up to 42" line size): 103 to 25,855 kPag (15 to 3,750 psig) *Minimum operating pressure varies by line size
Materials
Carbon steel and stainless steel

Features

  • Expedite flow disturbance detection with patented transducer synchronization that prevents interference and noise
  • Reduce measurement uncertainty with process alerts for wall buildup, liquids, blockage and deviating gas quality
  • Equipped with robust titanium encapsulated T-200 Transducers for optimal performance in wet, sour and corrosive environments.
  • T-200 Transducers are safely extractable under pressure without special tools (for line sizes up to 42")
  • Speed issue resolution with 3D view of the flow profile that indicates swirl, crossflow, asymmetry and turbulence
  • Reduce manual errors with automatic calculations of AGA 8 Compressibility and AGA 10 Speed of Sound
  • Simplify installation with two meters in one body; no need for an additional meter run or intermediate flanges
  • Streamline maintenance, extend calibration cycles and cut costs by easily tracking meter performance to baseline
  • Significantly reduce time previous spent on data analysis and troubleshooting with the new Smart Meter Verification Basic feature now included in the latest 3410 Electronics firmware update

Education

Interested in attending a training class?

Visit Course Listing!